WME TGL-16 Tabletop High Speed Refrigerated Centrifuge
WME TGL-16 applys to molecular biology, molecular chemistry and geneamp PCR. It has low-noise DC brushless motor and environmental compressor. When it reaches the highest speed,it can keep the temperature below -4℃.It can store 15 program for customers program freely.
PRODUCT DETAILS
Technical Parameters
Model | WME TGL-16 | Temp Acurracy | ±1℃ |
Order No. | 146000 | Compressor | Non-CFC unit(R404a) |
Max.speed | 16000rpm | Noise | ≦57dB(A) |
Max.RCF | 21532xg | Power Supply | AC220V±22V 50Hz 10A |
Max.Capacity | 12x5ml | Wattage | 700w |
Speed Acurracy | ±30rpm | Dimension(WxDxH) | 350x630x300mm |
Time setting range | 1min to 99min | Package Dimension(WxDxH) | 460x820x480mm |
Temp setting range | -20℃ to 40℃ | Net Weight | 65kg |
Order No.: 809100 Max.Speed: 16000rpm Max.RCF: 17800xg Rotor Cap.: 12x1.5ml Adaptor: 805004(0.5ml) 805005(0.2ml) | Order No.: 809200 Max.Speed: 12000rpm Max.RCF: 10142xg Rotor Cap.: 12x5ml Adaptor: 806103(0.5ml) 806104(1.5ml) | Order No.: 809300 Max.Speed: 15000rpm Max.RCF:21532xg Adaptor: 805004(0.5ml) 805005(0.2ml) | |||
Order No.: 807900 Max.Speed: 10000rpm Max.RCF: 9178xg Rotor Cap.: 36x1.5ml Adaptor: 805004(0.5ml) 805005(0.2ml) | Order No.: 807800 Max.Speed: 11000rpm Max.RCF: 13700xg Rotor Cap.: 48x0.5ml | Order No.: 809400 Max.Speed: 15000rpm Max.RCF:13800xg Rotor Cap.:3x8x0.2 PCR | |||
Order No.: 810500 Max.Speed: 16000rpm Max.RCF: 15300xg Rotor Cap.:18x0.5ml |
Vacuum blood collection tubes are widely used in blood collection for hospitals,caps has to be opened by hand after centrigation, so that it will affects the centrifugation efficiency and also increase the risk of bacterial infection.WME CTK32/WME CTK32R, WME CTK48/WME CTK48R, WME CTK80/WME CTK80R, WME CTK100/WME CTK100R, WME CTK120/WME CTK100R, WME CTK132/WME CTK132R,WME CTK150/WME CTK150R Automatic Decapping Centrifuge successfully solved the problem of caps,it is the right choice of the hospital.
Features
Applied to blood collection tubes and more than 90% tubes can be automatically decapped.
Applied to 100mm and 75mm length tubes.
LCD display for easier use.Driven by AC frequency-conversion motor,with functions of speed control,acceleration and deceleration.
RCF value can be automatically calculated.
Special damping set releasing the vibration.
Electronica interlock for better safety
Adaptor Operation Methods
The adaptor is used for 100mm length and 75mm length vacuum blood collection tube.
1.If you need separate two kinds of vacuum blood collection tube with different length at the same time, must to guarantee the adaptor layers in symmetrical position is the same, and same length tubes should be placed symmetrically in even number (see figure 1).
2.When using 100mm length vacuum blood collection tube, must assemble all three middle-plates and top plate(decapping plate)in place (see left picture in figure 2).
3.when using 75mm length vacuum blood collection tube, take off the top-plate at first, and then remove one layer middle-plate,only use two layers and at last reassemble the top-plate in place.
4.After centrifugation is finished, just take off the top- plate, the vacuum blood collection tube and the cap would be separated automatically. (see figure 3 and 4)